Switching the flow, not stopping the line
A diverter valve changes where material goes while the feed and the air keep running. Get the type right and a single line can serve several destinations; get it wrong and you inherit leakage into the dead leg, blockages and endless cleaning.
How a plug diverter makes the turn
A cylindrical plug carrying a bored passage rotates inside the valve body. A quarter-to-half turn aligns the bore with one outlet or the other, and the round opening lines up with the round conveying ports for a smooth transition.
Feed arrives
Material and conveying air enter through a single inlet. The line stays live throughout the changeover — no need to stop the feeder or isolate the air supply.
Plug rotates
A pneumatic rotary actuator turns the plug about 150°, though electric actuators and hand cranks are available. The user can choose pneumatic, electric or manual operation.
Bore aligns
The round hole in the plug matches the blow-through ports, giving a low-resistance path. There is no rubber seat to wear, which suits abrasive products.
Flow is redirected
Product is delivered to the selected destination. Several valves in series can spread one material across multiple points, or let it bypass a process step entirely.
Where plug types beat flap types
On coarse or large-particle products, a flap diverter can trap a pellet under the flap and leak material into the idle leg. A rotating plug avoids that trap. The trade-off is that highly sticky materials are a poor fit for plug diverters — they can pack around the plug and prevent it from sealing.
Duty envelope and construction
Representative values for the plug and three-way diverter range. Confirm the exact combination with your line pressure and layout.
| Types | Plug (pneumatic / gravity), ball-plug, rotary-plate and swing-plate constructions |
| Nominal size | DN50 to DN800 (approximately 2″ to 32″) |
| Working pressure | Atmospheric / low: below 0.1 MPa; medium: 0.15–0.35 MPa; high: above 0.35 MPa |
| Working temperature | −20 °C to 200 °C as standard; up to 500 °C on specified designs |
| Pipeline angle | 22.5°, 30°, 45°, 60° and 90° options to suit the layout |
| Actuation | Pneumatic, electric or manual; AirTAC and Festo cylinders available |
| Body & plug materials | SS304 / 304L / 316 / 316L, WCB cast steel, QT500 ductile iron; other grades on request |
| Connection | ANSI B16.5 150 lb, GB, HG, SH, or to customer drawing; flanged or pipe-welded ends |
| Surface finish | Polished conveying passages, up to 400# for food and pharmaceutical service |
| Typical media | Flour, bran, starch, grain, feed, sugar, plastic granules, cement, lime, dust and fly ash |
Installation rule worth remembering
Never switch a diverter while material is still moving through the line. Where a diverter shares a flow path with a slide gate, close the slide gate first, change the diverter, then reopen it. A magnetic or inductive position switch should confirm the plug has completed its travel before the downstream equipment is allowed to run.
Frequently asked questions
Straight answers to the questions that arrive most often.
Are you a trading company or a manufacturer?
We are the factory. The business grew out of a state-owned grain machinery works and has been building rotary valves, diverter valves and magnetic separators for decades. Production runs on two sites with in-house machining, which also lets us handle non-standard and OEM/ODM orders.
What if the valve we receive does not match the specification?
If the delivered product does not match the agreed description or our written promise, we will put it right — up to and including a full refund. The specification is agreed in writing with the drawing before production starts.
How long is the lead time?
Standard models are normally held in stock and can be ready in about a week. Non-standard valves are engineered to order and typically take around 35 days from drawing approval. We arrange production within 30 days of order confirmation and deposit, and ship within 10 days of receiving the balance.
What are your payment terms?
For orders up to USD 1,000 we ask for payment in full in advance. Above USD 1,000 the usual terms are 40% by T/T as a deposit, with the balance settled before shipment.
How is the equipment packed and shipped?
Machines are wrapped with a protective film inside and a waterproof outer layer. Anything less than a full container is crated in a wooden case, and the unit is secured with steel rope inside the container so it arrives in the condition it left the factory.
What warranty and support come with the valve?
Spare parts and the motor carry a 12-month warranty from acceptance, with ongoing online technical support after that. Engineers can assist with installation and commissioning, and enquiries are normally answered with a price and proposal within 24 hours.
What information do you need to size a valve?
Four things are enough to start: the material being handled, the required throughput (t/h or m³/h), the pressure above and below the valve, and the preferred body material. Knowing the equipment fitted above and below the valve helps us avoid interface problems later.
Related engineering notes
How a rotary valve works
Pocket filling, tip-speed limits, airlock sealing and the role of the vented housing.
Read the note → Engineering note 02Materials & duties
Match rotor, seal and body to sticky, hot, abrasive or hygienic products.
Read the note → Product pageDiverter valve range
Model options, flange choices and request a quotation for the DV series.
View product →