How to calculate rotary airlock valve capacity

One formula links valve displacement, rotor speed, fill factor and bulk density to throughput. Use it to narrow the size, then confirm against the real material.

By Cheegers Engineering Team · Published 27 November 2026 · Updated 27 November 2026

The short answer

Q = 0.06 x V x R x F x B

Capacity in tonnes per hour follows directly from four duty variables. The 0.06 factor converts litres per minute into cubic metres per hour.

SymbolMeaningUnitTypical value
QCapacity / handling ratet/hTarget duty
VValve displacement per revolutionL/r2.5 - 2000 L
RRotor speedr/min20 - 50 r/min
FFill factor-0.6 free-flowing; lower for sticky products
BBulk densityt/m³ (kg/dm³)Measure poured sample
0.06Unit factor (60 min/h ÷ 1000 L/m³)-Constant

Worked example. A 56 L valve at 26 r/min, fill factor 0.3, handling a product with bulk density 0.12 t/m³:

Q = 0.06 × 56 × 26 × 0.3 × 0.12 = 3.14 t/h

The same relationship works in reverse. To deliver 6 t/h at 25 r/min, fill factor 0.3 and bulk density 0.5 t/m³, the required displacement is 6 ÷ (0.06 × 25 × 0.3 × 0.5) = 26.7 L per revolution.

Rotor geometry

Calculating pocket volume from dimensions

When the rotor is designed from scratch, displacement is derived from the swept annulus minus the vanes.

V (L) = [ π (R² - r²) L - (R - r) t L n ] ÷ 1,000,000

R = rotor radius, r = shaft radius, L = vane length, t = vane thickness, n = number of vanes. All dimensions in mm.

InputValue
Vane length / rotor diameter380 mm / 350 mm
Shaft diameter / vane thickness90 mm / 8 mm
Number of vanes10
Calculated displacement30.19 L per revolution
Speed limits

Check rotor tip speed before finalising

Capacity is not only a question of running faster. Excessive tip speed carries product back towards the inlet and reduces net delivery.

v (m/s) = π × D (mm) × n (r/min) ÷ 60,000

Ideal tip speed is 0.5 - 0.7 m/s. A 400 mm rotor at 32 r/min gives π × 400 × 32 ÷ 60,000 = 0.67 m/s, inside the recommended band.

Drive sizing

Sprocket ratio and inverter frequency

Valve speed is set by the sprocket pair and, where fitted, the inverter frequency.

CalculationFormulaExample
Valve speednvalve = nmotor × Zdrive ÷ Zdriven41 r/min from a 20-tooth / 39-tooth pair
Inverter frequencyf = 50 × nrequired ÷ nfull50 × 18 ÷ 24 = 37.5 Hz

Where the gearmotor delivers 24 r/min at full frequency and the duty needs 18 r/min, set the inverter to 37.5 Hz.

Reference data

Bulk density and DN sizing

Bulk density has the same proportional effect on mass capacity as displacement. Poured density of the actual sample should always be measured.

MaterialBulk density (kg/m³)MaterialBulk density (kg/m³)
Wheat750 - 820Cement1000 - 1300
Maize / corn750 - 800Sugar830
Soybean720 - 760Salt970
Rice750 - 800Fly ash400 - 450
Wheat flour550 - 600Rice husk96 - 160
Feed pellet / mash400 - 620Wood shavings200 - 300
FlangeTypical displacement (L)Motor power (kW)
DN10020.18
DN1502.5 - 30.55
DN2005 / 90.75 / 1.1
DN25010 / 161.1 / 1.5
DN30016 / 251.5
DN35030 / 502.2
DN40040 / 602.2
DN450853

These are common configurations. The RV platform is available from DN100 to DN1800 with 2.5 L to 2000 L per revolution.

Practical questions

Frequently asked questions

Answers to the questions that come up during valve sizing.

What is the capacity formula for a rotary airlock valve?

Q = 0.06 x V x R x F x B, where Q is capacity in t/h, V is valve displacement in L per revolution, R is rotor speed in r/min, F is the fill factor and B is bulk density in t/m3. The 0.06 factor converts litres per minute into cubic metres per hour.

What fill factor does Cheegers use?

Cheegers uses a fill factor of 0.6 for free-flowing products in the published sizing formula. Lower fill factors are applied to cohesive, sticky or poorly flowing materials. The final value is confirmed against a sample of the real product.

How do I size a valve from a target throughput?

Rearrange the formula: V = Q / (0.06 x R x F x B). For 6 t/h at 25 r/min, fill factor 0.3 and bulk density 0.5 t/m3, the required displacement is 26.7 L per revolution. Select the next standard pocket volume above that figure.

What rotor tip speed is recommended?

An ideal rotor tip speed is 0.5 to 0.7 m/s. Calculate it with v = pi x D x n / 60,000, where D is rotor diameter in mm and n is speed in r/min. A 400 mm rotor at 32 r/min runs at about 0.67 m/s.

How is pocket volume calculated from rotor geometry?

V = [pi x (R2 - r2) x L - (R - r) x t x L x n] / 1,000,000 in litres, where R is rotor radius, r is shaft radius, L is vane length, t is vane thickness and n is the number of vanes, all in mm.

How do gear ratio and inverter frequency affect valve speed?

Valve speed = motor speed x driving sprocket teeth / driven sprocket teeth. Inverter frequency f = 50 x required speed / full-frequency speed. A motor running at 18 r/min against a 24 r/min full-frequency output needs 37.5 Hz.

Does bulk density change the required valve size?

Yes. Capacity is directly proportional to bulk density, so the same valve handles roughly twice the mass flow of a material with twice the bulk density. Always confirm the poured bulk density of your specific product.

Where can I get a checked calculation for my duty?

Send the material, target throughput, bulk density, operating temperature and installation layout to Cheegers engineers. We confirm pocket volume, speed and fill factor before issuing a dimensioned drawing.